MULTI VAC

Valve Testing

All new heads including bare heads have a valve put in and ports are vacuum tested.

VACUUM LEAK DOWN TEST

Water System Check

Vacuum leak down test is done on the water system to ensure there is no leaks.

TIME

Hardness Testing

New Aluminum cylinder heads must hardness test from 100 - 120 HB.

Button label

Mira Centronic

Valve Seat Cutting

Computerized set up, 3 angle valve seat cutting

Warren & Brown

Valve Grinding

Pink Stellite grinding wheel achieves a perfect finish.

Magna Flux

Crack Testing

Magnetic cracking testing with a black light for cast iron cylinder heads.

Zanrosso

Surface Grinding

Cylinder head gasket face machining using PCD and CBN tools.

STRAIGHT EDGE

Head Gasket Face

Head gasket face is straight edge checked.